China ECS-7000MU Integrated Monitoring Terminal for Construction Equipment - China Supplier China ECS-7000MU Integrated Monitoring Terminal for Construction Equipment - China Supplier China ECS-7000MU Integrated Monitoring Terminal for Construction Equipment - China Supplier China ECS-7000MU Integrated Monitoring Terminal for Construction Equipment - China Supplier China ECS-7000MU Integrated Monitoring Terminal for Construction Equipment - China Supplier

ECS-7000MU Integrated Monitoring Terminal for Construction Equipment

Price:元1000
Industry Category: Machinery
Product Category:
Brand: ECS-7000MU
Spec: ECS-7000MU


Contact Info
  • Add:西安市雁塔区翠华南路60号, Zip:
  • Contact: 张简
  • Tel:15299505139
  • Email:

Other Products

Description
Additional Information

Overview of Integrated Building Equipment Monitoring System

The integrated building equipment monitoring system centrally monitors and controls the air conditioning, power supply and distribution, cold and heat sources, water supply and drainage, ventilation, and other systems within a building or building complex. It performs energy efficiency tracking control on the aforementioned system equipment to achieve efficient operation, dynamic real-time management, fault warning, and green energy conservation.

I. ECS-7000MF Fan Energy-saving Controller

It can detect the actual electrical power of the fan, and the fan and fire damper are set for interlocked start-up. Through intermittent operation, local exhaust, and the CO concentration in the basement, the controller automatically controls the energy-saving operation of the fan. Smoke exhaust and ventilation fans are set with fire protection priority; when there is a fire alarm input, they automatically switch to high-speed operation and stop the operation of other ventilation and exhaust fans. Equipment room supply and exhaust fans.

For more product information or product pricing, please call our company.

Product quotation contact number: 15O-O29O-668O

Please contact Manager Zhang: 一五二--二九〇--六六八〇 (same as VX)

We will wholeheartedly provide you with project drawing design optimization and configuration plan quotations!!!

II. ECS-7000MU Elevator Energy-saving Controller

Completes status and fault monitoring of equipment such as elevators, fire pumps, and sprinkler pumps; 35mm standard rail-mounted installation.

Water pump energy-saving controller;

It can automatically control the start and stop of water pumps based on corresponding liquid level signals, automatically select start and stop water pumps based on cumulative operating time, motor monitoring, energy-saving evaluation, energy-saving control, etc.; 35mm standard rail-mounted installation.

III. ECS-7000MT Cooling Tower Centralized Control Energy-saving Controller

1. Integrates the secondary circuit of the cooling tower electrical control cabinet

2. Manual/remote-automatic control; interlock control; pump group status display; pump group combination configuration and automatic balanced wear function; frequency converter control

3. Real-time tracking of pump group working efficiency and recording

4. Self-check function, provides fault location and cause of pump group and electrical control box for quick maintenance

IV. ECS-7000MZK Cold and Heat Source Centralized Control Energy-saving Controller

1. Performs cluster control on cold and heat source equipment, chilled water pump groups, cooling water pump groups, and cooling tower groups

2. Real-time tracking of unit working efficiency and recording, with LCD text display of real-time data and status, debugging settings

3. 1 USB, 2 RS485 communication interfaces, can supply power to external communication links

4. 16 universal inputs, 6 digital outputs, 4 analog outputs

5. Serial port supports BACnet M, Modbus-RTU, etc.

6. 35mm standard rail-mounted installation

V. ECS-7000MLS Refrigeration Unit Energy-saving Controller

1. Integrates the secondary circuit of the cooling pump electrical control cabinet 2. Used to collect various control points and status points of the chiller unit; manual remote automatic control; interlock control; unit status display; butterfly valve control; unit combination configuration and automatic balanced wear function, etc. 3. Working mode can be set: direct start, soft start, frequency conversion start; self-check function, provides fault location and cause of the unit and electrical control box for quick maintenance of equipment

VI. ECS-7000MD Chilled Water Pump Energy-saving Controller

1. Integrates the secondary circuit of the chilled water pump electrical control cabinet

2. Manual/remote-automatic control; interlock control; pump group status display; pump group combination configuration and automatic balanced wear function; frequency converter control

3. Real-time tracking of pump group working efficiency and recording

4. Self-check function, provides fault location and cause of pump group and electrical control box for quick maintenance

VII. ECS-7000MQ Cooling Water Pump Energy-saving Controller

1. Integrates the secondary circuit of the cooling water pump electrical control cabinet

2. Manual/remote-automatic control; interlock control; pump group status display; pump group combination configuration and automatic balanced wear function; frequency converter control

3. Real-time tracking of pump group working efficiency and recording

4. Self-check function, provides fault location and cause of pump group and electrical control box for quick maintenance

VIII. Introduction to ECS-7000S Energy Consumption Monitoring System

The municipal energy consumption monitoring platform can upload the energy consumption data (water, electricity, gas, heating) of various buildings within its jurisdiction equipped with energy consumption monitoring systems to the municipal platform in real time. Through the municipal platform, various types of energy consumption data are summarized, statistically analyzed, and uploaded to the provincial platform, facilitating government departments at all levels to understand the real energy consumption status of various public buildings and providing data support for the energy consumption supervision of large public buildings.

IX. ECS-7000GLJ Energy Consumption Data Collector Configuration Instructions

The ECS-7000GLJ energy consumption data collector requires configuration of relevant parameters before use. The ECS-7000GLJ energy consumption data collector is connected to the local area network, and parameters are configured by remotely logging into the ECS-7000GLJ energy consumption data collector via an IE browser.